13

4.5 R

OLL

S

ENSOR

I

NSTALLATION

Mount the roll sensors to the included roll
sensor brackets using the machine screws and
nylon lock nuts. (Figure 13)

The roll sensors must be mounted

tightly to the brackets.

Figure 13: Mounting the Roll Sensor

When mounting the roll sensors use the
following guidelines and refer to Figure 14.
a) The smaller the distance between A and B

in Figure 14, the better the performance
will be.

Distance A cannot be more than 12”.

b) The roll sensors must not be mounted

below the pivot point.

c) Ensure the roll sensors are sitting relatively

level when the sprayer chassis and boom are
level.

d) Both roll sensors must be mounted with the

circular AMP connector facing towards the
Right-Hand Wing (when looking from the
rear of the sprayer).