4 main lift sensor installation – NORAC UC4+BC+RG7 User Manual
Page 16
13
4.4 M
AIN
L
IFT
S
ENSOR
I
NSTALLATION
1. Assemble the main lift sensor bracket
(B11) as shown in Figure 10.
Figure 10: Main Lift Sensor Bracket
2. The bracket can then be mounted to
the lowest frame member on the center
section of the sprayer. The bracket
should be mounted so the sensor
mounting collar is in approximately the
center of the sprayer and ahead of the
boom (Figure 11).
The sensor mounting collar must
not be behind the sprayer’s
wheel.
The General Mounting Rules for
UC4+ Ultrasonic Sensors, from
the previous section, must be
followed.
3. Mount the sensor onto the sensor
mounting collar (Figure 10).
Figure 11: Main Lift Sensor Mounted in the Rogator Boom (looking from above of
boom)
Bracket Tube
Sensor
Mounting Tab
Sensor Mounting
Collar
Bracket Base
Main Lift Sensor
Bracket