beautypg.com

5 roll sensor installation – NORAC UC4+BC+RG4 User Manual

Page 18

background image

15

4.5

R

OLL

S

ENSOR

I

NSTALLATION

Mount the roll sensors to the included roll
sensor brackets using the machine screws
and nylon lock nuts, as illustrated in Figure
13
.

The roll sensors must be

mounted tightly to the brackets.

Figure 13: Mounting the Roll Sensor

to the Roll Sensor Mounting Bracket

When mounting the roll sensors use the
following guidelines and refer to Figure 14.
a) The smaller the distance between A and

B in Figure 14, the better the
performance will be.

Distance A cannot be more than

12”.

b) The roll sensors must not be mounted

below the pivot point.

c) Ensure the roll sensors are sitting

relatively level when the sprayer chassis
and boom are level.

d) Both roll sensors must be mounted with

the circular AMP connector facing
towards the Right-Hand Wing (when
looking from the rear of the sprayer).

Figure 14: Mounting Guidelines for Center Pivot Sprayers

Connectors towards
Right-hand Wing 