NORAC UC4+BC+RG6 User Manual
Page 27
24
2. Connect the UC4+ power cable (C10)
to the UC4+ Control Panel in the
sprayer cab. Ensure that both plugs
(P16A and P4) are connected to the
receptacles of the panel (Figure 24).
Ensure the UC4+ control panel’s
power is OFF for the remaining
installation (Bottom of switch
pressed IN). Use caution when
handling the 12 V power line of
the Rogator wiring.
3. The 3-pin AMP plug (P3) on C10 is
connected to an auxiliary 12 V power
connection in the Rogator cab. If an
appropriate connector(s) cannot be
found it may be necessary to use cable
C14 and connect onto the Rogator
wiring (Figure 24). Refer to Section
5 for wiring information.
4. There are two access panels on the
back of the cab exterior, on the driver’s
right hand side, that provide access to
the sprayer’s wiring and electronics.
Inside the panel closest to the sprayer
front, there is a removable “knockout”
in this electronics cavity (Figure 25).
See Figure 26 for power and ground
connections inside of Access Panel 2.
When connecting C14, install the
provided 15A automotive fuse into the
slot beside the +12V power connection.
Figure 25: Interior of Access Panel 1 () and Access Panel 2 ()
Figure 26: Power and Ground Connections
Connect
GROUND
wire here
Connect +12V wire
(spade terminal)
here and install 15A
fuse