2 valve mounting – NORAC UC4+BC+RG6 User Manual
Page 24
21
4.6.2 Valve Mounting
Figure 21: Valve Mounting Location
1. Mount the NORAC valve (V01) on the
sprayer using the valve mounting
bracket (B10).
2. As shown in Figure 21, screw short
side of the threaded rods into the
bottom of the valve block at least 3/8".
The valve mounting holes are drilled and
tapped 3/8 NC-1" deep.
3. Tighten the Hex nuts to hold the rods.
4. Put the mounting bracket on the other
side of the tube and tighten with the
spring washers and the Hex nuts.
5. Cut excess off of the rods, if necessary.
If using bolts, the bolts should
thread into the valve block at
least 3/8". The valve mounting
holes are drilled and tapped 3/8
NC-1" deep. The rule of thumb
for bolt length is 1-1/2" longer
than the tube size.
Figure 22: Valve Mounting Example
You must ensure no hydraulic
components will interfere with
any sprayer parts or be pulled
tight at any time.