2 chassis roll sensor mounting – NORAC UC4+BC+OM1 User Manual
Page 14
11
4.4.2 Chassis Roll Sensor Mounting
1. It is often best to cable tie the chassis
roll sensor in place. When mounting the
chassis roll sensor follow the guidelines
and refer to Figure 9.
The chassis roll sensor must be
mounted on a portion of the
sprayer that does not pivot and is
as close to the boom frame roll
sensor as possible (Figure 7).
a) Make sure you are using the roll
sensor with the temperature probe
(E03).
b) Ensure the roll sensor is level with
respect to the chassis.
c) The AMP (circular) connector
MUST exit towards the right
hand wing.
d) Make sure the temperature probe is
able to reach the side of the valve
block.
Figure 9 – Chassis Roll Sensor Mounting
2. Fasten the temperature probe to the
UC4+ valve block, using the supplied
3/8”x1/2” bolt as shown in Figure 10.
3. Cable-tie the temperature probe cable
and AMP (circular) connector securely
to a frame member.
Check that the roll sensors and
cables will not interfere with, or
come into contact with any parts of
the sprayer.
Figure 10 – Temperature Probe Attached
to the Valve Block