When installing the UC4+

sensors (E02), start with the
smallest serial number on the left

hand side proceeding to the
largest serial number on the right
hand side (Figure 9).

5. Sensor cables should run through the

mounting bracket tube and then behind
the member the bracket is mounted
onto. Cable-tie the connector in place.
The cable must not be allowed to hang
below the boom (Figure 6).

Figure 6: Another Acceptable

Mounting

Avoid mounting sensors in

locations where they may read
from parts of the boom as shown
in Figure 7.

Figure 7: Poor Mounting

(Sensor Reading off Boom)

General mounting rules for UC4+
ultrasonic wing sensors:

a) In its lowest position, the sensor mouth

must be 9 inches or more from the
ground.

b) The bottom of the sensor must be at

least 9 inches in front of the spray
nozzles.

c) The bottom of the sensor must be at

least 9 inches above the spray nozzles.

d) Ensure that there are no obstructions

within a 12-inch diameter circle
projected directly below the center of
the sensor.

e) The sensor should be approximately

vertical at normal operating heights.

Figure 8: Sensor Mounting Guidlines


A

B

B

D

C

Ultrasonic
Acoustic Cone