Milwaukee Tool 2216-20NST User Manual

Page 3

background image

4

5

ASSEMBLY

Symbology

Read Operator’s Manual

Double Insulation

Risk of Electric Shock

Earth (Ground)

Danger, Warning, or Caution -
Consult the operators manual for
additional safety information.

Battery

European Conformity Mark

Underwriters Laboratories, Inc.,
United States and Canada

1

Canadian Conformity Mark

Cat III

Classifi cation of transient
overvoltages, based on nominal
line voltage to earth.

Fuse

Do not dispose of this product as
unsorted municipal waste.

WARNING

To avoid an electrical hazard,

turn the rotary dial to OFF and disconnect the
test leads before replacing batteries.

Dial Position

Range

Resolution

Accuracy

Voltage AC

6mV-600mV/6V/

60V/600V

0.1mV/0.001V/

0.01V/0.1V

±(1.0% + 3 dgt) (45~500Hz)

±(2.0% + 3 dgt) (500~1000Hz)

Voltage DC

600mV/6V/

60/600V

0.1mV/0.001V/

0.01V/0.1V

±(0.5% + 2 dgt)

Hz

Hz

Hertz

2Hz-99.99Hz/999.9Hz/

9.999kHz/50kHz

0.01Hz/0.1Hz/

0.001kHz/0.01kHz

±(0.1% + 2 dgt)

Sensitivity: 10Vp-p

Resistance

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

0.1/0.001k/0.01k/

0.1k/0.001MΩ

±(1.0% + 5 dgt)
±(1.0% + 5 dgt)

40MΩ

0.01MΩ

±(2.0% + 5 dgt)

Continuity

Cont Buzzer

0-600.0Ω

0.1 Ω

Beeper sounds at 30 Ω and below

Capacitance

100μF / 1000μF

0.1μF / 1μF

±(1.9% + 2 dgt)

Current AC

0.04A - 6A / 10A

0.001A/0.01A

±(1.5% + 3 dgt) (45~500Hz)

Current DC

6A/10A

0.001A/0.01A

±(1.0% + 3 dgt)

Functions

* This is a True-RMS instrument. All AC voltage and

AC current readings are True-RMS values.

* Input impedance: Voltage DC: 10MΩ; Voltage AC:

10MΩ // less than 100pF

* Overload protection:
Voltage DC, Voltage AC, and Hertz: AC/DC 720V for

10 second

Current DC & Current AC: AC/DC 20A for 10 sec.

Resistance, Continuity, and Capacitance: AC/

DC 600V for 10 second

* Maximum measurement time: 1 minute at 10A, rest

time 20 minutes minimum

* Minimum frquency measurement is 2Hz
* Minimum AC Current measurement is 0.040A
* For AC Voltage, and AC Current:
Additional Accuracy by Crest Factor (C.F.): Add

6.0% for C.F. 1.0 ~ 2.0

Add 7.0% for C.F. 2.0 ~ 2.5
Add 9.0% for C.F. 2.5 ~ 3.0
Max. Crest Factor: 1.6 for 6600 ~ 5000 digits
2.0 for 5000 ~ 3000 digits
3.0 for 3000 ~ 0 digits
* Measurement accuracy of square wave and trun-

cated waveforms at 1kHz is unspecifi ed.

Changing the Batteries
Replace batteries when the low battery indicator

is displayed.

1. Turn rotary dial to OFF and disconnect the test

leads.

2. Unscrew and remove

battery door.

3. Insert two (2) AA batteries,

according to the polarity
marked in the battery
compartment.

4. Close the battery door and

tighten screws securely.

OPERATION

Before Use
Confi rm the rotary dial is set to the correct position,
the instrument is set to the correct measurement
mode, and the hold function is disabled. Otherwise,
desired measurement cannot be made.

LCD Backlight

Press the backlight button to turn the LCD back-
light on and off. The backlight will turn off after about
10 minutes of inactivity and can be turned back on
by pressing the backlight button again.

DANGER

To avoid electrical shock:

Never make measurement on a circuit in
which voltage over 600 volts AC exists.
Do not use with the battery cover removed.
Keep fi ngers behind the guards and away
from test lead tips during measurements.

CAUTION

Readings may fl uctuate or

be infl uenced in noisy environment.

1. Set the dial to

position.

2. Connect the red test lead to the

VΩ terminal and the black test
lead to the COM terminal.

3. Connect the test leads to the

circuit under test. The reading
is displayed.

1. Set the dial to position.

2. Connect the red test lead to the

VΩ terminal and the black test
lead to the COM terminal.

3. Connect the red test lead to the

positive (+) side and black test
leads to the negative (-) side of
the circuit under test.
The reading is dis-
played. A reversed
connection is indi-
cated as a negative
value.

DANGER

To avoid electrical shock:

Never make measurement on a circuit in
which voltage over 600 volts DC exists.

Do

not use with the battery cover removed. Keep
fi ngers behind the guards and away from test
lead tips during measurements.

DC Voltage

WARNING

Only use MILWAUKEE test

leads with the MILWAUKEE Digital Multimeter.
Inspect test leads for continuity before each
use. Do not use if the readings are high or
noisy.

0

V

AC

0

V

DC

Making a Measurement

AC Voltage