78M6613 Evaluation Board User Manual

Rev. 2

9

2.3 Basic Connection Setup

Figure 1 shows the basic connections of the 78M6613 Evaluation Board for use with external equipment.

The 78M6613 Evaluation Board is powered through the USB cable. This same USB cable provides the

communications link between the host PC and the 78M6613 Evaluation Board.

The 78M6613 Evaluation Board accepts 120 VAC and 230 VAC (nominal) up to 300 VAC (max).

Figure 1: 78M6613 Evaluation Board Connections

Attach an AC source to J3 (Neutral) and J6 (Line). Attach the AC load to J4 (Neutral) and J8 (Line).

Note: The hardware and embedded firmware are capable of measuring two outlets or AC loads. For more

information, contact Maxim application support.

Connect the USB

Port to the Host PC

Neutral

Neutral

Line

Line

Connect to

the Load to

be Measured

Connect to AC

wall outlet