5 Default Values

The following default values are used to build the MAPI library:

struct MPU_CParms_t MPU_CParams =
{

Unsigned Char Channels = 0
float C_Wcal = 120W
float C_Vcal = 120V
float C_Ical = 1A
Unsigned Integer t C_Pcal = 0


float C_Wtolerance = 10mA
float C_Vtolerance = 10mV
float C_Itolerance = 10mA
float C_Ptolerance = 0.1 degree


Unsigned Char C_Vavg_cnt = 3
Unsigned Char C_Iavg_cnt = 3
Unsigned Char C_Wavg_cnt = 3


Unsigned Integer C_Vmax_cnt = 10
Unsigned Integer C_Imax_cnt = 10
Unsigned Integer C_Wmax_cnt = 10


Unsigned Integer C_Wrate_cal = 4860 (shall not change)
Unsigned Integer C_Tempcal (read-only)

};

#define DefaultTIQ

10 //Default Time Increment Query


struct VIT_t xdata mapi_tVIT =
{

0x01,

//Channel 1

0.00,

//Current_I;

0.00,

//Current_V;

};

struct Relay_Config_t xdata RlyConfig =
{

0x00,

//unsigned char Relay_CTL;

0x64,

//unsigned int SeqDlyTime;

0x01,

//unsigned int DeEnergizedTime;

0x01,

//unsigned int EnergizedTime;

0x00,

//InvertPNonLatch

};