4.5 Zero Crossing and Relay Control
4.5.1 MAPI_RelayConfig()
Purpose
Read/Write relay configuration values. Relay configuration is applicable to all
channels/outlets.
Synopsis
void MAPI_RelayControl( IN Bool Operation, OUT/IN struct
Relay_Config_t Relay_Config);
Where Relay_Config_t is defined as:
struct Relay_Config_t
{
Unsigned Char
Relay_CTL;
Unsigned Integer
SeqDlyTime;
Unsigned Integer
DeEnergizedTime;
Unsigned Integer
EnergizedTime;
Unsigned Char
InvertPNonLatch;
};
Parameters
Operation
Input parameter.
TRUE (1) = set operation. FALSE (0) = get operation,
Relay_Config will all be output parameter.
When Operation = TRUE:
Relay_CTL
Output parameter.
This parameter is output only. It is set via
MAPI_RelayControl()
.
SeqDlyTime
Input parameter.
Set the new Sequence Delay Time in 10ms
units. Delay time is time between turning
Relays ON (close circuit). Default value is 10
100ms.
DeEngergizedTime
Input parameter.
Time in mseconds + 1msecond to delay after
open circuit.
EngergizedTime
Input parameter.
Time in msecond + 1msecond to delay after
close circuit.
InvertPolarity
Input parameter.
Bit 1 = Polarity (0 = non-inverted). Bit 0 =
Latch type (0 = non-latched).
Notes:
Sequence Delay Time will be used between turning relays ON.
Energized Delay Time is used as the delay time to wait
immediately after a zero-crossing before close circuit.
DeEnergized Delay Time is used as delay time to wait
immediately after a zero-crossing before open circuit.
Return Codes None.