Maxim Integrated 78M6612 M-API Library User Manual
Page 21

UG_6612_036
78M6612 M-API Library User Guide
Rev. 1.00
21
4.2.1.3 MPU Library Inputs
The following inputs can be modified (and saved to Flash) using API calls. For more information on
register descriptions, refer to the 6612_OMU Firmware Description Document.
Category
Name
LSB
MPU
Address
Description
Common Alarm
Threshold
Temperature
D0
D1
Min Temperature Alarm Threshold
Max Temperature Alarm Threshold
Frequency
D2
D3
Min Frequency Alarm Threshold
Max Frequency Alarm Threshold
Voltage (A)
D4
D5
D6
SAG (A) Voltage Alarm Threshold
Min Voltage (A) Alarm Threshold
Max Voltage (A) Alarm Threshold
Outlet Specific
Alarm Thresholds
NB
WB
Current - Outlet 1
D8
D9
Max Current Alarm Threshold
Power Factor - Outlet 1
DA
DB
DC
DD
Power Factor Alarm - Threshold
Power Factor Alarm + Threshold
Current - Outlet 2
DE
DF
Max Current Alarm Threshold
Power Factor - Outlet 2
E0
E1
E2
E3
Power Factor Alarm - Threshold
Power Factor Alarm + Threshold
Total Current
E4
E5
Max Current Alarm Threshold
Alarm Mask
Alarm Mask for Status Registers
E6
32-BIT alarm mask (0=masked)
Alarm Mask
Alarm Mask for Alarm DIO4
E7
32-BIT alarm mask (0=masked)
Sensor Scaling
Voltage - V(A)
Current -Outlet 1
Current - Outlet 2
A0
A2
A4
VMAX A
IMAX Outlet 1 (IA)
IMAX Outlet 2 (IB)
Cost Factor
Cost
AA
AB
Cost per KWh
Cost Unit string
Relay Control
Relay Configuration
AC
AD
AE
AF
Polarity, Latch type
Sequence Delay
Energize Delay
De-energize Delay
Calibration
Calibration
Configuration
Parameters
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
Tolerance on Phase Calibration
Calibration Type
Calibration Voltage (Target)
Calibration Current (Target)
Calibration Phase (Target)
Tolerance on Voltage Calibration
Tolerance on Current Calibration
Average Count for Voltage
Average Count for Current
Max Iterations for Voltage
Max Iterations for Current
Tolerance on Watts Calibration
Average Count for Watts
Max Iterations for Watts
Calibration WRATE
Calibration Temperature
Calibration Wattage (Target)
Creep Threshold
Current -Outlet 1
Current - Outlet 2
A1
A3
Imin(IA) - "creep" or squelch level
Imin(IB) - "creep" or squelch level