LAARS U.H.E. - Service Manual User Manual
Page 17
U.H.E Service Manual
Page 17
Thermostat Sensor (Thermistor) Replacement Procedure
Step 5.
Fold back insulation just in front of burner to
expose temperature sensor (see photo below).
Step 6.
Disconnect temperature sensor from
harness (see photos at right).
Step 7.
Remove temperature sensor (1-1/16" hex, deep well socket) from heater.
Note:
Using a deep well socket will allow room inside socket
for sensor connector and wires.
Step 8.
Apply thread sealing tape or applicable thread lubricant to threads of new sensor. Install new thermostat
sensor and Connect to wire harness from step 6.
Step 9.
Fold insulation back into place. Be sure there are no wires in contact with burner.
Step 10. Restore 120 volt power supply and water supply to water heater, check and repair any
leaks found. Confirm proper operation following the lighting instructions on the lighting
instruction label or the lighting instruction located in the installation and operating
instruction manual.
Step 11. Replace surround cover on top of heater.
Step 1.
Position main power switch to “OFF”
Step 2.
Disconnect (unplug) water heater from
120 volt power source.
Step 3.
Drain water heater down to a point below the
top of the tank.
Step 4.
Un-latch and remove top surround cover
from top of heater.
WARNING
120 volt potential exposure. Isolate the
appliance and reconfirm power is
disconnected using a multi-meter.
17
Disconnect sensor
from harness
Hot Surface Ignition Models
Insulation folded back
to expose temperature
sensor