beautypg.com

1c. technical assistance, 1a. introduction, 1b. warranty – LAARS Mighty Therm HH-PH (Sizes 175-400) - Installation, Operation and Maintenance Instructions User Manual

Page 3

background image

Mighty Therm HH-PH Hydronic Boilers

Page 3

A

8-1/2 in.

(216mm)

INLET

OUTLET

TOP VIEW

C

C

OPTIONAL

VENT CAP FOR
OUTDOOR USE

DRAFTHOOD

DRAFTHOOD MUST
BE INSTALLED IN
THE FIELD

HEADER
LOCATION

OUTLET

40-9/16 in. (1030mm)

INLET

5-1/2 in.
(140mm)

26-1/2 in.
(673mm)

SIDE VIEW

V

30-3/16 in. (767mm)

B

include the boiler serial number and model (this

information can be found on the rating plate),

installation date, and name of the installer. Shipping

costs are not included in the warranty coverage.

Some accessory items are shipped in separate

packages. Inspect everything for damage immediately

upon delivery, and advise the transporter of any

shortages or damage. Any such claims should be filed

with the transporter. The transporter will not accept a

claim from the shipper, Laars.

The warranty does not cover damage caused by

improper installation, operation, or field modification.

1C. Technical Assistance

Consult Laars or your local company

representative with any questions or problems

involving the specification, installation and operation

of Laars equipment. An experienced technical support

staff is ready to assist in assuring the proper

performance and application of Laars products.

SECTION 1.
General Information

1A. Introduction

This manual provides installation and operation

instructions for the Model HH and PH Hydronic

Boilers, Sizes 175 through 400. Review all application

and installation procedures completely before

proceeding with the installation. Experience has

shown that most operating problems are caused by

improper installation.

The HH-PH boilers are offered in a basic

configuration (see Figure 1). On PH boilers the pump

is factory installed. On HH boilers the pump is field

installed.

1B. Warranty

The HH-PH boilers are sold with a limited

factory warranty.

Make all warranty claims to an authorized Laars

representative or directly to the factory. Claims must

Figure 1. General Configuration.

Gas Connection

C*

C

Size

Water

C

(Indoor

(Indoor

V

Connect.

U.S. Only

w/ Vent

w/o Vent

Vent

Nat.

Propane

Size

A

B

(Outdoor)

Damper)

Damper)

Dia.

Size

in.

mm in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in. mm

175

¾

19

½

13

38

18

457

26½

673

14

1

/

16

357

28½

724

23½

597

6 152

250

¾

19

½

13

38

22½ 572

31

787

18

1

/

16

473

30½

775

24¾

629

7 178

325

¾

19

½

13

38

26¾ 679

35¾

908

19

3

/

16

488

25

7

/

8

657

8 203

400

¾

19

½

13

38

31¾ 806

40¼

1022

22

5

/

8

575

26

7

/

8

683

9 229

*Vent damper only required on indoor installations, sizes 175 and 250.
Note: Dimensions may vary.