Press the function keys, Key; the right digit starts flashing. use, Key; now the second digit is flashing. use – KERN & SOHN VHS 2T1 Addendum User Manual
Page 3: Key; the third digit is flashing. use
![background image](/manuals/697337/3/background.png)
Press the function keys
PRE-
TARE
,
TOTAL
and
TARE
to enter the last adjustment value,
too, at “0000.0“, as described above, press the
TARE
key to confirm all
segments until only the NET +
~ display arrows flash.
To confirm, press the
TARE
key for c. 4 sec. The display reverts to “AF00“.
Again the display shows the last adjustment value.
To exit adjustment mode, press the
TOTAL
key; the scales show e. g. AP 11.
(internal value)
Press
the
TARE
key for c. 4 sec.; system reverts to weighing mode. On the
display appears the current weight placed on the forks. Adjustment is
complete and you may now take off the adjustment load.
or:
2. MULTIPLE-POINT ADJUSTMENT
The scales must be turned on and you have already carried out a reset to zero.
Now, press the
PRE-
TARE
key for approximately 20 seconds. The scales show the
value of the first adjustment point; the NET display arrow is flashing.
Use the
PRE-
TARE
,
TOTAL
and
TARE
function keys to enter the existing adjustment
weight as follows:
Briefly press the
TARE
key; the right digit starts flashing.
Use
PRE-
TARE
or
TOTAL
to set this digit according to the first adjustment weight, e. g.
for 250 kg, set "2".
To confirm, briefly press the
TARE
key; now the second digit is flashing.
Use
PRE-
TARE
or
TOTAL
to set this digit to “5”.
To confirm, briefly press the
TARE
key; the third digit is flashing.
Use
PRE-
TARE
or
TOTAL
to set this to “2“, the hundreds digit at “2“ and, possibly the
thousands digit at “0“, as required. To confirm, press the
TARE
key until only the
NET display arrow flashes.
Import the adjustment weight (in this case the 250 kg above).
To confirm press the
TARE
key for c. 4 sec. The display reverts to “AF00“. The
display shows again the first adjustment value. The first adjustment load (250
kg) can now be taken off.
Press
the
TOTAL
key, the ~ display arrow is flashing, the medium adjustment
value can be entered.
KERN VHB_VHS