Press, Button, Press the numeric – KERN & SOHN VHS 2T1 User Manual
Page 12: Up or down, Key for three seconds, to confirm the value, The tare weight is now activated, Net” appears, The weighing system is loaded: press the, The weighing system is unloaded: press, The tare weight is now activated and stored

¾
Press
PRE-
TARE
button
¾
Press the numeric
TOTAL
up or down
PRE-
TARE
key until the flashing number has reached
the desired value.
¾
To move to the next segment, press the key
TARE
¾
Repeat this action until the display shows the desired tare value.
¾
To activate the tare weight (but not for storing): Press the
TARE
key for three
seconds, to confirm the value.
The tare weight is now activated.
“NET” appears.
If the system is loaded at this moment, the net value of the weighed weight
appears on the display.
If the system is unloaded, the system indicates the entered tare value negative.
The entered value remains active until the weighing system is turned off, a new
tare weight entered, a new load tared (See 7.3.) or if a reset to zero is carried
out:
¾
The weighing system is loaded: Press the
PRE-
TARE
key for two seconds. The tare
value will be reset to zero and the system reverts to standard weighing mode.
or
¾
The weighing system is unloaded: Press
TARE
button A reset to zero is
carried out and the system reverts to standard weighing mode.
¾
To activate and store the tare weight: Confirm all segments by pressing the
TARE
key.
The tare weight is now activated and stored.
“NET” appears.
If the system is loaded at this moment, the net value of the weighed weight
appears on the display.
If the system is unloaded, the entered tare value is shown negative.
The entered value remains active even after the system was turned off, until a
new tare weight is entered, a new load tared (See 7.3.) or a reset to zero is
carried out.
¾
The weighing system is loaded: Press the
PRE-
TARE
key for two seconds. The tare
value will be reset to zero and the system reverts to standard weighing mode.
or
¾
The weighing system is unloaded: Press button. A reset to zero is carried
out and the system reverts to standard weighing mode.
VHB/VHS-BA-e-1012