beautypg.com

2 lc-208p/lc-208p combination, Proximity elevator control panel – Keri Systems LC-208 Proximity Elevator Control User Manual

Page 19

background image

Proximity Elevator Control Panel

1530 Old Oakland Road, Suite 100

01879-001 Rev. E

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 19 of 22

LC-202P/LC-208P

Quick Start Guide

5.4.2

LC-208P/LC-208P Combination

Perform the following wiring instructions to accommodate an elevator application using two LC-
208P panels; up to 16 floors (for 32 floors, add a third LC-208P and continue the daisy-chain wiring
to the third panel).

1. Make a complete set of connections to the first LC-208P panel. Refer to Section 5.3 on page 14

for all connections to the LC-208P. This panel must have the master elevator controller (the
controller with address 1).

2. Daisy-chain the Antenna and Ground reader connections from the terminal strip on the first

panel to the terminal strip on the second panel. Make the connections per the information in
Table 8 and Figure 12.

Figure 12: LC-208P to LC-208P Wiring Connections

Table 8: LC-208P to LC-208P

First LC-208P Reader

Terminal Strip

Second LC-208P Reader

Terminal Strip

Reader Antenna

Reader Antenna

Reader Ground

Reader Ground

This manual is related to the following products: