Quick Start Guide

LC-202P/LC-208P

5.4

Wiring Multiple Panels Together

Up to 24 floors can be controlled using a combination of LC-202Ps and LC-208Ps; the first eight
floors must be controlled by an LC-208P. After that, any combination of LC-202Ps and LC-208Ps
can be added to meet your floor requirements.

5.4.1

LC-208P/LC-202P Combination

Perform the following wiring instructions to accommodate an elevator application using an LC-
208P and one or more LC-202P panels (9 to 16 floors).

1. Make a complete set of connections to the LC-208P panel. Refer to Section 5.3 on page 14 for

all connections to the LC-208P.

2. Daisy-chain the Antenna and Ground reader connections from the LC-208P panel to the LC-

202P panel(s). Make the connections per the information in Table 6 and Figure 10 on page 17.

3. Daisy-chain the TxRx+, TxRx-, and Shield Network Communication connections from the

terminal strip on the LC-208P to each of the LC-202P panels. Make the connections per the
information in Table 7 and Figure 11 on page 18.

4. Refer to Section 5.2.1 on page 9 for the LC-202P floor relay connections.
5. Refer to Section 5.2.4 on page 14 for the LC-202P panel power connections.

Table 6: LC-208P to LC-202P

LC-208P Reader Terminal Strip LC-202P TB-5 or TB-6

Reader Antenna

Pin 1

Reader Ground

Pin 4

Table 7: LC-208P to LC-202P Panel

Network Communication Wiring

LC-208P Panel

LC-202P TB-1

TxRx-

Pin 1

TxRx+

Pin 2

Shield

Pin 3