Wiegand Elevator Control Panel
2305 Bering Drive
01942-001 Rev. D
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]
Page 2 of 24
Quick S
tart Guide
LC-502W/LC-508W
2.0
Hardware and Software Operating Requirements
All standard hardware and software requirements for Doors software apply (refer to the Doors
Users Guide – P/N 01914-100). To support elevator control, the following additional software and
firmware requirements must be met.
•
The Doors software must be at revision 4.10 or greater.
•
The controller firmware must be at revision 8.4.12 or greater.
3.0
Specifications
3.1
Unit Dimensions
•
LC-500W Controller PCB
-
7.00 inches high by 6.00 inches wide by .50 inches deep, including wiring connectors
-
(17.78 cm by 15.25 cm by 1.27 cm)
•
LC-500W Controller PCB with an LCD-1 Alpha/Numeric Display
-
7.00 inches high by 6.00 inches wide by .75 inches deep, including wiring connectors
-
(17.78 cm by 15.25 cm by 1.91 cm)
•
LC-500W Controller PCB with an SB-500 Satellite Board (with or without an LCD-1 Alpha/
Numeric Display)
-
7.00 inches high by 6.00 inches wide by .75 inches deep, including wiring connectors
-
(17.78 cm by 15.25 cm by 1.91 cm)
•
LC-502W Enclosure
-
13.00 inches high by 9.00 inches wide by 4.00 inches deep
-
(33.02 cm by 22.86 cm by 10.16 cm)
•
LC-508W Enclosure
-
18.50 inches high by 15.25 inches wide by 4.00 inches deep
-
(47.00 cm by 38.75 cm by 10.20 cm)
3.2
Operating Temperature and Humidity Range
•
0°F to 140°F (-18°C to 60°C)
•
0% to 90% Relative Humidity, non-condensing
3.3
Power Requirements
•
12 VDC @ 750 mA for the LC-502W panel
•
12 VDC @ 3 A for the LC-508W panel