beautypg.com

Wiegand elevator control panel – Keri Systems LC-508 Wiegand Elevator Control User Manual

Page 14

background image

Wiegand Elevator Control Panel

2305 Bering Drive

01942-001 Rev. D

San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]

Page 14 of 24

Quick S

tart Guide

LC-502W/LC-508W

All other reader connections to the remaining LC-502W panels are made per the following rules.

1. The reader data lines must be daisy-chained from the master elevator panel to all other elevator

panel data inputs – Data 0 to Pin 1 of TB-5 and TB-6 and Data 1 to Pin 7 of TB-5 and TB-6 on
the LC-502W panels.

2. The reader ground line must be daisy-chained from the master elevator panel to all other

elevator panel antenna grounds to provide a standard ground reference for all panels – Pin 4 of
TB-5 and TB-6 on the LC-502W panels.

Make the data line daisy-chain connections per the information in Table 5 and Figure 9 on page 15.

Table 4: Distribution Amplifier to

Master Elevator Panel

Amplifier WDA-TB-2

Panel TB-5

Pin 1

Pin 1

Pin 2

Pin 2

Pin 3

Pin 3

Pin 4

Pin 4

Pin 5

Pin 5

Pin 6

Pin 6

Pin 7

Pin 7

Table 5: Master Elevator Panel to Slave

Elevator Panels

Master Panel TB-5

Slave Panel TB-5 or TB-6

Pin 1

Pin 1

Pin 4

Pin 4

Pin 7

Pin 7

This manual is related to the following products: