Kenton Pro-2000 mk1 User Manual
Page 18

17
specified memory location and also to the edit buffer (current setup)
the data will be immediately utilised and the display will be updated.
You may change the block number of a memory dump without causing any
problem. For example, data that came from memory 6 could be returned to
the current setup by merely changing the 06 in byte [ 7 ] to a 00.
Parameter data are stored in the following addresses.
Address
Function
Range
Notes (
see end
)
00h
A Receive chan
0 - 15
{ 1 }
01h
A note priority
0 - 2
02h
A trig / retrig
0 - 1
03h
A transpose
232 > 0 > 24
{ 2 }
04h
A pitchbend range
0 - 24
05h
A portamento speed 0 - 255
06h
A portamento cont #
253 - 0 - 119
{ 3 }
07h
A lfo depth controller #
252 - 0 - 119
{ 4 }
08h
A lfo max val
0 - 127
09h
A lfo assign
0 - 1
0Ah
A gate select
0 - 7
5 modes used
0Bh
A fine tune val
129 > 0 > 127
129>0 = -ve
0Ch
A scale val
129 > 0 > 127
129>0 = -ve
0Dh
A v/o hzv select
0 - 1
0Eh
B Receive chan
0 - 15
{ 1 }
0Fh
B note priority
0 - 2
10h
B trig / retrig
0 - 1
11h
B transpose
232 > 0 > 24
{ 2 }
12h
B pitchbend range
0 - 24
13h
B portamento speed 0 - 255
14h
B portamento cont #
253 - 0 - 119
{ 3 }
15h
B lfo depth controller #
252 - 0 - 119
{ 4 }
16h
B lfo max val
0 - 127
17h
B lfo assign
0 - 1
18h
B gate select
0 - 7
5 modes used
19h
B fine tune val
129 > 0 > 127
129>0 = -ve
1Ah
B scale val
129 > 0 > 127
129>0 = -ve
1Bh
B v/o hzv select
0 - 1
1Ch
C Receive chan
0 - 15
{ 1 }
1Dh
C Transmit chan
0 - 15
{ 1 }
1Eh
D Receive chan
0 - 15
{ 1 }
1Fh
D kadi / wasp select
0 - 1
20h
Ax1 Receive chan
0 - 15
{ 1 }
21h
Ax1 Cont #
239 > 0 > 119
{ 6 }
22h
Ax1 min val / fine tune
0 > 64 > 127
{ 5 }
23h
Ax1 max val / scale
0 > 64 > 127
{ 5 }
24h
Ax1 reset val
0 > 64 > 127
{ 5 }
25h
Ax1 lfo cont #
252 - 0 - 119
{ 4 }
26h
Ax1 lfo max val
0 - 127
27h
Ax1 lfo assign
0 - 1
28h
Ax2 Receive chan
0 - 15
{ 1 }
29h
Ax2 Cont #
239 > 0 > 119
{ 6 }
2Ah
Ax2 min val / fine tune
0 > 64 > 127
{ 5 }