beautypg.com

2 setting the dip switch – Citizen Systems iDP-562 User Manual

Page 23

background image

iDP-562 User’s Manual

CITIZEN

18

6.2 Setting the Dip Switch

iDP-562CNL / CN has Dip Switch with which you can select the followings to meet your computer’s function.
Selection of “CR” and “LF” code function.
Please refer to the table below.

DSW-1

DSW-2

DSW-3

CR and LF code

When CR code comes

are valid function.

immediately after full

When the buffer is blank.

*OFF

CR code is selected

buffer printing

by the DSW-2
and 3.

*OFF

CR code is void

*OFF

CR code is valid

ON

CR code is valid

ON

CR code is void

CR code is ignored

When LF code comes

LF code is valid.

immediately after full

When the buffer is blank.

ON

LF code is selected

buffer printing

by the DSW-2
and 3.

*OFF

LF code is void

*OFF

LF code is valid

ON

LF code is valid

ON

LF code is void

It is recommended to set the DIP switches in accordance with your host’s output DATA format.

DATA Form

DSW-1 DSW-2 DSW-3

DATA + CR

OFF

OFF

OFF

DATA + LF
DATA + CR + LF

ON

OFF

OFF

DATA + LF + CR

USA

GERMANY

FRANCE

UK

DSW-4

*OFF

OFF

ON

ON

Foreign character
Selection

DSW-5

*OFF

ON

OFF

ON

DSW-6

Not for use

DSW-10

NOTE:

* Marks are a “Factory Setting”