beautypg.com

2 setting of dip switch and slide switch – Citizen Systems iDP-562 User Manual

Page 14

background image

iDP-562 User’s Manual

CITIZEN

9

5.2 Setting of DIP Switch and SLIDE Switch

Following function are available by setting DIP switch and SLIDE Switch.
Selection of “CR” and “LF” code function.
Please refer to the table below.

DSW-1

DSW-2

DSW-3

CR and LF code

When CR code comes

are valid function.

immediately after full

When the buffer is blank.

*OFF

buffer printing

*OFF

CR code is void

*OFF

CR code is valid

CR code is selected by
the DSW-2 and 3.

ON

CR code is valid

ON

CR code is void

CR code is ignored

When LF code comes

When the buffer is blank.

ON

immediately after full buffer
printing

*OFF

LF code is void

*OFF

LF code is valid

LF code is valid.
LF code is selected by
the DSW-2 and 3.

ON

LF code is valid

ON

LF code is void

It is recommended to set the DIP switches in accordance with your host’s output DATA format.

DATA Form

DSW-1 DSW-2 DSW-3

DATA + CR

OFF

OFF

OFF

DATA + LF
DATA + CR + LF

ON

OFF

OFF

DATA + LF + CR

Foreign character

USA

GERMANY

FRANCE

UK

Selection

DSW-4

*OFF

OFF

ON

ON

DSW-5

*OFF

ON

OFF

ON

ODD

EVEN

No Check

Parity check

DSW-6

*OFF

ON

*OFF

ON

DSW-7

OFF

OFF

*ON

*ON

Selection of DATA

DSW-8

ON

7 bit DATA

bit length

*OFF

8 bit DATA

SSW *OFF

9600

4800

2400

1200

Selection of Baud Rate

-1

ON

1200

600

300

150

DSW-9

*OFF

OFF

ON

ON

DSW-10

*OFF

ON

OFF

ON

NOTE:

* Marks are a “Factory Setting”.