Mm aa iinn tt ee nn aa nn cc ee – Intex CS15110 Krystal Clear 2012 User Manual
Page 29

163
SAVE THESE INSTRUCTIONS
Page 29
(163) MODEL CS15110 SAND FILTER PUMP & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 11/08/2011
English
MM
AA
IINN
TT
EE
NN
AA
NN
CC
EE
ELECTROLYTIC CELL CLEANING
COPPER ELECTRODE CLEANING
If the pool water is hard (high mineral content) the cell may require periodic manual
cleaning. To maintain maximum performance, we recommend that you open and
visually inspect the electrolytic cell
(22) once every month.
The following steps are some instructions on how to clean your cell.
1.
Switch off the unit, unplug the power cord from the electrical socket.
2.
Disconnect the hose (12) from the electrolytic cell (22) outlet and cover the
outlet with the drain outlet cover (3) from the 6-way valve (see drawings 36
and 37).
3.
Remove the electrolytic cell from the 6-way valve outlet by unscrewing the
electrolytic cell (22) collar (see drawing 38).
4.
Pour kitchen grade vinegar into the cell to immerse the titanium plates (see
drawing 39). Soak for about 1 hour and then flush with a high-pressure
garden hose.
5.
Reverse steps 2 to 4 to reconnect the electrolytic cell.
1.
Switch off the unit, unplug the power cord from the electrical socket.
2.
In a counter-clockwise motion, unscrew the electrical plug collar from the
copper electrode cell, and remove the electrical plug from electrode cell (see
drawings 40 and 41).
3.
Unscrew the copper electrode cell collar, then remove the electrode cell and
place it on a bucket.
4.
Pour kitchen grade vinegar into the bucket until the copper electrode cell is
immersed (see drawing 43). Soak for 1 hour and then flush with a
high-pressure garden hose.
5.
Reverse steps 2 to 4 to reconnect the copper electrode cell.
37
38
36
39
3
22
22
41
42
40
43
24