Cooper Lighting Square Straight Steel SSS User Manual
Page 2

S T R E E T W O R K S O u t d o o r L i g h t i n g S o l u t i o n s
173
C o o p e r L i g h t i n g
S Q U A R E S T R A I G H T S T E E L
P O L E S
Mounting
Fixture
No. &
Accessories
Shaft
3
Wall
Height
Base
Mounting
Location
Arm
(Ground
Square
Straight
Steel
Size
Thickness
(ft.)
Type
Finish
& Type
of Arms
Lengths
Lug)
S
S
S
5
A
20
S
F
M
1
X
G
Bolt Anchor
Base
Circle
Bolt
Shaft
Bolt
Net.
Max. Fixture
Mtg.
Catalog
1, 2
Wall
Square
Dia.
Proj.
Size
Dia. &.
Wt.
EPA (Sq. Ft.)
4
EPA (Sq. Ft.)
4
Load—Include
Height
Number
Thickness
(In.)
(In.)
(In.)
(In.)
Length (In.)
(Lbs.)
At Pole Top
2' Above Pole Top Bracket (Lbs.)
MH
S
BC
BP
B
AB
70
80
90
100
70
80
90
100
10
SSS4A10SF
.120
10 1/2
11.0
4 1/2
4
3/4 x 25 x 3
96
39.8
29.9
23.2 18.4
33.0
24.8 19.3 15.3 150
15
SSS4A15SF
.120
10 1/2
11.0
4 1/2
4
3/4 x 25 x 3
133
19.6
14.4
10.8 8.2
17.2
12.7 9.5
7.3
150
20
SSS4A20SF
.120
10 1/2
11.0
4 1/2
4
3/4 x 25 x 3
152
12.9
9.1
6.5
4.6
11.7
8.2
5.9
4.2
200
25
SSS4A25SF
.120
10 1/2
11.0
4 1/2
4
3/4 x 25 x 3
208
8.7
5.6
3.6
2.1
8.0
5.2
3.3
2.0
200
20
SSS5A20SF
.120
10 1/2
11.0
4 1/2
5
3/4 x 25 x 3
202
21.9
15.7
11.6 8.5
19.9
14.3 10.5 7.7
200
25
SSS5A25SF
.120
10 1/2
11.0
4 1/2
5
3/4 x 25 x 3
248
15.5
10.5
7.2
4.8
14.3
9.8
6.6
4.4
200
30
SSS5A30SF
.120
10 1/2
11.0
4 1/2
5
3/4 x 25 x 3
293
8.2
4.6
2.1
--
7.7
4.3
2.0
--
300
35
SSS5M35SF
.188
10 1/2
11.0
4 1/2
5
3/4 x 25 x 3
480
11.8
7.1
3.8
1.5
11.1
6.6
3.6
1.4
300
25
SSS6A25SF
.120
12 1/2
12.5
5
6
1 x 36 x 4
295
24.1
16.8
12.0 8.5
22.2
15.6 11.1 7.8
200
30
SSS6A30SF
.120
12 1/2
12.5
5
6
1 x 36 x 4
347
14.0
8.7
5.0
2.5
13.1
8.2
4.7
2.3
300
30
SSS6M30SF
.188
12 1/2
12.5
5
6
1 x 36 x 4
505
26.4
18.1
12.5 8.4
24.7
16.9 11.6 7.9
300
35
SSS6M35SF
.188
12 1/2
12.5
5
6
1 x 36 x 4
584
19.7
12.7
7.9
4.4
18.6
12.0 7.5
4.2
300
35
SSS6X35SF
.250
12 1/2
12.5
5
6
1 x 36 x 4
696
28.9
19.7
13.4 8.9
8.7
18.6 12.7 8.4
300
39
SSS6M39SF
.188
12 1/2
12.5
5
6
1 x 36 x 4
647
15.4
9.1
4.8
1.8
14.6
8.7
4.6
1.7
300
39
SSS6X39SF
.250
12 1/2
12.5
5
6
1 x 36 x 4
822
23.5
15.4
9.8
5.7
22.4
14.6 9.3
5.4
300
NOTES: 1 Catalog number includes pole with anchor bolts with double nuts (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING).
2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180° from single arm.
3 Shaft size, base plate, anchor bolts and projections may vary slightly—all dimensions nominal.
4 EPA’s based on shaft properties with wind normal to flat. EPA’s calculated using base wind velocity as indicated plus 30% gust factor.
M A C H I N I N G F O R R E C TA N G U L A R A R M S
[ A d d a s s u f f i x ]
Designation
Designation
Designation
Quantity
Letter & Number
Letter & Number
Letter & Number
& Location
M1
E1
Z1
Single
M2
E2
Z2
2 @ 180°
M3
E3
Z3
3 @ 120°
M4
E4
Z4
4 @ 90°
M5
E5
Z5
2 @ 90°
M6
E6
Z6
3 @ 90°
M7
E7
Z7
2 @ 120°
NOTES: Refer to Fixture Drilling Options on page 160.
A C C E S S O R I E S
A=1/2" tapped hub
1
B=3/4" tapped hub
1
C=Convenience outlet
2
G=Grounding lug (max. wire #8 AWG)
H=Additional hand hole and cover—
12" below pole top—90° from hand hole.
NOTES: 1 Location is 3' above base–90° from hand hole.
2 Outlet is located 4' above base and on same side of pole
as hand hole, unless specified otherwise. Receptacle not
included, provision only.
M O U N T I N G O P T I O N S
[ A d d a s s u f f i x ]
Fixed Tenon
Designation
O.D.
Length
Number
(In.)
(In.)
1
2 3/8
3 1/2
2
2 3/8
4
3
3 1/2
5
9
3
4
7/8''
2 13/16''
3/4'' dia.
hole
(2) 3/8"
dia. holes
3 7/8''
D R I L L I N G PAT T E R N
Type “M” [RCL, Landau, Galleria and Vision]
Type “E” [Concourse III]
Type “Z” [Credenza and Cirrus]
3/4'' dia.
hole
(2) 5/8''
dia. holes
2 7/16''
2 5/16''
4 7/8''
O.D.
LENGTH
9/16" [14mm]
dia. hole (3)
4 7/8" [124mm]
4" [102mm]
2 7/16" [62mm]
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R
: S S S 5 A 2 0 S F M 1 X G
NOTE:
Specifications and dimensions subject to change without notice.