Fixture lengths & mounting locations, Suspenslon and end set ordering illustrations, Control – Philips Lightolier EG1-4 User Manual
Page 3: Power feed end set, Cable/cord assembly, Cable assembly, Eg1-4, Lightoliizir, Philips, Lighting systems
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Lighting Systems
EG1-4
Page 3 of 5
Fixture Lengths & Mounting Locations
I-«—48^' (121.92cm)—
4-Foot Run
iT
Ti
5' (152.40cm) OA
[------------------------ 96^' (243.84cm) -
9' (274.32cm) OA
!-•— 48^' (121.92cm)
-----------
,|T T-
-96“ (243.84cm)-
13' (396.24cm) OA
16-Foot Run
20-Foot Run
24-Foot Run
t
-48^' (121.92cm)—
17' (518.16cm) OA
-96^' (243.84cm)------
Energos 1-Light T5 per 4' (121.92cm) (Nominal) Louver
4' (121.92cm) Run
8' (243.84cm) Run
4' (121.92cm)
Module
1
8' (243.84cm)
Module
1
End Set
1
1
Cable Joiner
12' (365.76cm) Run
1
1
1
1
16' (487.68cm) Run
2
1
1
- 20' (609.60cm) Run
1
2
1
2
^ 24' (731.52cm) Run
3
1
2
h----------- ------------96^' (243.84cm) ------------
----------- 96^' (243.84cm)------------
--
-96^' (243.84cm)-
21' (640.08cm) OA
-96" (243.84cm)-
25' (762.00cm) OA
---------------------- 96^' (243.84cm)-----------------------► ---------------------- 96^' (243.84cm)-----------------------►
Suspenslon and End Set Ordering Illustrations
Power Feeds
Consult Lamp and Ballast System data to determine Input watt requirements for
ballast used on project to determine loading for each run. Mulfiply fhe fötal num
ber of ballasfs by fhe Inpuf waffage per ballasf, and fo defermlne ampacify divide
fhe fötal watts by the system voltage. 10 Amps for 3-wlre end sefs, 7 Amps for
4-wlre and 5-wlre end sefs, maximum.
Control
Consulf appropriafe ECS (Energos Confrol Sysfems) specificaflon sheef for ordering
producf uflllzing occupancy confrols. ECS specificaflon sheef numbers direcfly cor
relare fo sfandard Energos specificaflon sheef numbers.
Power Feed End Set
Whife, 3 Wire Cord
Whife, 4Wlre Cord
Whife, 5 Wire Cord
Aluminum, 3 Wire Cord
Aluminum, 4 Wire Cord
Aluminum, 5 Wire Cord
EG1EC36W
EG1EC36W4
EG1EC36W5
EG1EC36A
EG1EC36A4
EG1EC36A5
Ceiling Grid Kit:
CGK
Cable/Cord Assembly
Single Cable & Power Cord:
EGCC36
Single Cable & 4 Wire Power Cord:
EGCC36X4
Single Cable & 5 Wire Power Cord:
EGCC36X5
Because mosf ceilings are whife, all canopies ship as whife
unless specifically ordered otherwise.
Both CGK and CGKP ship with two types of clips
(sfandard and slot T).
Eor mounting fixtures directly to the T grid, order
one CGK per non-power suspension point and one
CGKP per powered suspension point.
The CGKP will Include a special canopy with flex
coupler, grid clips and addiflonal clips fo mounf fhe
juncflon box fo the top of the grid nearby. J-Box
and flex condulf provided by others.
Cable Assembly
Single Cable: EGC36
Ceiling Grid Kit, Power:
CGKP
Job Information
Type:
631 Airport Road, Pall River, MA 02720 • (508) 679-8131 • Eax (508) 674-4710
We reserve the right to change details of design, materials and finish.
PHILIPS
LIGHTOLIIzir