3 connecting to local switch client through a pvc, 4 non-zero vpis, Non-zero vpis -14 – Cabletron Systems 6A000 User Manual
Page 56

4-14 SmartCell 6A000 User Guide
PVC Connections
Switch Administration
6.
Configure the workstations for the same subnet and VPI/VCI pair = 0/101.
The broadcasting workstation on port A1 can send traffic to the receiving workstations on ports B2, B3, and C1.
4.5.3
Connecting to Local Switch Client Through a PVC
All PVC connections to the SmartCell 6A000 local clients use B4 (the CPU port) as the HighPort.
Follow these instructions to connect an end node to a SmartCell 6A000 local client through a point-to-point PVC.
1.
Use
add pvc
to create the PVC.
SmartCell ZX # add pvc
ConnType(PTP) :
LowPortID() : a1 LowVPI() : 0 LowVCI() : 100 HighPortID() : b4 HighVPI() : 0 HighVCI() : 100 FwdTrafficDescriptorIndex() : 2 BkwTrafficDescriptorIndex() : 2 SmartCell ZX # 2. Use add ipatmclient to create the IP over ATM local client. SmartCell ZX # add ipatmclient ClientNumber(0) : 2 ServerType(NONE) : local ServerAddress() : IPAddress() : 10.1.1.0 NetMask(255.0.0.0) : MTU(9180) : SmartCell ZX # 3. Use add ipatmpvc to associate the end node’s IP address with the PVC. SmartCell ZX # add ipatmpvc ClientNumber(0) : 2 DestinationIP() : 10.1.1.22 DestinationVPI(0) : DestinationVCI(33) : 100 SmartCell ZX # 4. Connect the end node to port A1 of the SmartCell 6A000. 5. Configure the end node with IP address 10.1.1.22, subnet mask 255.0.0.0, and VPI/VCI pair = 0/100. 4.5.4 Non-zero VPIs The SmartCell 6A000 uses 12 bits to define VPI/VCI pairs. The vccmask determines how many of the 12 bits are used for the VPI and how many are used for the VCI. The vccmask uses a 2-bit register to hold four different VPI/VCI 12-bit combinations. Table 4-1 shows the registers and the values that come preconfigured on the SmartCell 6A000.