1.
Enter the
start LECS
command to activate LANE server services on this switch.
SmartCell ZX # start lecs
NOTICE - 'LECS' ***** LECS started *****
SmartCell ZX #
2.
Create an ELAN on your SmartCell 6A000 switch by executing the
add elan
command. The
following is an example.
SmartCell ZX # add elan
ELANNumber(0) : 1
<1 is used instead of the default, (0)
ELANName(ELAN001): Marketing
ConnectMethod(SVC): ELANType(802.3) Multipoint(YES) : MTU(1516) : Distribute(PROXY) : SmartCell ZX # 3. Create a client for the switch on the ELAN. For example, enter SmartCell ZX # add laneclient ClientNumber(0) :1 LanName(ELAN001) : Marketing < ELAN name is Marketing, not the default, (ELAN001) ServerType(LECS) : ServerAddress() IPAddress() : 90.1.1.1 < IP address and subnet mask are included only as examples NetMask(255.0.0.0): 255.255.255.0 MTU(1516) : SmartCell ZX # Note The command add laneclient always prompts you with a subnet mask that is appropriate for the IP address. However, if necessary, you can change the subnet Note When you create a client, it automatically finds the LECS address using ILMI. As the local client joins the ELAN, the following messages are sent to the Event log: NOTICE - 'ZLESSRV' LES Join 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4: 14:41:82:00 NOTICE - 'ZLESSRV' BUS Connect 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:D4: 14:41:82:00 Caution Never create an ELAN (or ELAN client) with the same subnet as the SmartCell
mask to correspond to the strategy employed within your networks.
6A000 Ethernet port.