beautypg.com

2 uni routes, Uni routes -5 – Cabletron Systems 6A000 User Manual

Page 47

background image

SmartCell 6A000 User Guide 4-5

Switch Administration

ATM Routing

4.2.2

UNI Routes

Use the

add ATMRoute

command to create UNI routes. For example, connect an end station adapter (with MAC address

00:11:22:33:44:55) to port A2 of the SmartCell 6A000. If the adapter does not support ILMI or its ILMI is
incompatible with the SmartCell 6A000, you must create a static UNI route between the adapter and port A2 of the
SmartCell 6A000.

1.

Enter the

show netprefix

command to obtain the netprefix of port A2

SmartCell ZX # show netprefix

PortNumber(ALL) : a2

Port# NetPrefix

============================================================================

A2 39:00:00:00:00:00:00:00:00:00:14:59:00

SmartCell ZX #

2.

Reconfigure the adapter with an ATM address made from the netprefix of port A2 and the adapter’s
MAC address: 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00.

3.

Use the

add ATMRoute

command to create a static UNI route that specifies port A2 and the adapter’s

new ATM address.

SmartCell ZX # add atmroute

PortNumber(A1) : a2

AtmAddress() : 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00

PrefixLength(152) :

Index(0) :

Type(Internal) :

Scope(0) :

MetricsTag(0) :

SmartCell ZX #

4.

Enter the

show ATMRoute

command to check that the UNI route was added.

SmartCell ZX # show atmroute

AddressNumber(ALL) :

No. Port Route Address Type Protocol

================================================================================

1 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80 I MGMT

2 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81 I MGMT

3 -- 39:00:00:00:00:00:00:00:00:00:14:59:00 I PNNI

4 A2 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55 I MGMT

5 -- 39:00:00:00:00:00:00:00:00:00:28:e9:80 I PNNI

6 -- 39:00:00:00:00:00:00:00:00:00:28:f5:00 I PNNI

7 B4 47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I MGMT

8 B2 52:00:00:00:00:00:00:00:00:00:14:51:80 I MGMT

SmartCell ZX #SmartCell ZX #

The UNI route appears in the table as route number four (No. 4).

Note

For UNI routes to work with certain devices, ILMI may also need to be disabled
on the SmartCell 6A000. Use the

set PortConfig

command to disable ILMI on

the SmartCell 6A000 on a per-port basis.