TROUBLESHOOTING

Symptom

Check

Measures to take

The air from the air

dryer is cold.

Isn’t the air dryer temperature

adjustment button set to “OFF”

status?

Please adjust as the proper

temperature by pressing the air

dryer temperature adjustment

button.

Water leaks in areas

other than the

nozzles.

Water leaks on the T-shaped

connector.

Check that the rubber packing is

inserted in the T-shaped connector

and firmly tighten the nut again.

Water leaks on the connection

part of the bidet hose.

Push the bidet hose to the

connection part completely.

Water leaks on the filter.

Check whether the filter was

damaged or not.

Water comes out

while the bidet is

not in use.

What water comes out between the nozzles after cleansing is to clean

the nozzles, not a malfunction.

In some cases, water drops around the nozzles may fall down in the

toilet. It is that the water drops remaining on the nozzle surface after

the nozzle cleaning drop into the toilet. It is not a malfunction.

If you plug in the

power cord, the

rear cleansing

nozzle come out

and go in.

It is the initialization process of the nozzle position, not a product

malfunction.

There is a noise

coming from the

bidet.

While the water heater is in operation, a noise is generated in a normal

condition.

If the bidet is in power saving mode, as the seat and the warm water temperature

are set to low temperature, it may be felt relatively cold when you sit on. If the bidet

power saving mode is cancelled, the temperature set at the last use is maintained.

For canceling the power saving mode, see page 11 on this manual.