Tools needed, Installation, Wiring – Interlogix SuperBus 2000 2X20 User Manual
Page 2: Before you begin

•
Follow the wire length limits outlined in the specific panel
Installation Instructions between the touchpad and control
panel.
The following must be observed in UL installations
•
The touchpad hardwire input must not be used for fire
alarm initiating devices.
•
Only UL-listed devices may be connected to the touchpad
hardwire input.
•
The touchpad hardwire input can be configured for
normally closed or normally open protection devices.
•
For UL installations with UltraGard and Concord (software
versions 1.0–1.6) panels, do not use the touchpad
hardwire input.
Tools Needed
• Drill
with
bits
• Screwdrivers
•
#6 screws and anchors (included)
•
Panhead screws for a gang box installation
•
Saw or utility knife for cutting wallboard
Note: Do not use screws larger than #6 or the touchpad
will not seat properly onto the back-plate.
Installation
The touchpad can be installed on a wall or in a gang box.
To mount the touchpad on a wall:
1. Separate the mounting bracket from the back-plate by
loosening the two bottom screws and unlatching the tabs
from the mounting slots (see Figure 1 below).
2. Place the back-plate on the wall and mark the four
mounting holes and the wire access hole (see Figure 2
below). Be sure to leave a 1-inch clearance on all sides of
the back-plate.
3. Drill holes and insert appropriate anchors.
4. Secure the back-plate to the wall with included screws.
5. Cut a hole in the wall where the wire access hole was
marked to pull your cable through.
Figure 1: Touchpad mounting slots
MOUNTING SLOTS
CABLE OPENING
OPENING FOR CONNECTOR
3101G03B.DSF
LOOSEN BOTTOM SCREWS (X2)
To mount the touchpad in a gang box:
1. Separate the mounting bracket from the back-plate by
loosening the two bottom screws and unlatching the tabs
from the mounting slots (see Figure 1 above).
2. Line up the gang box mounting holes with the holes on the
gang box (see Figure 2 below).
3. Secure the back-plate to the gang box with panhead
screws.
Note: Do not overtighten screws or the back-plate may
bind and prevent the touchpad from mounting properly.
Figure 2: Back plate and mounting holes
3101G02B DS4
GANG BOX MOUNTING HOLES (X2)
BACK PLATE MOUNTING TABS (X3)
WALL MOUNTING HOLES (X4)
WIRE
ACCESS
HOLE
Wiring
Wiring consists of connecting the touchpad wiring harness to
the panel terminals. You may also connect an optional
hardwire sensor to the touchpad hardwire input wires.
Before You Begin
1. Disconnect the panel AC power transformer and backup
battery (turn off power switch on UltraGard panels).
2. Run a 4-conductor, 22-gauge wire cable from the panel to
the touchpad location.
2
SuperBus 2000 2X20 LCD Alphanumeric Touchpad Installation Instructions