12
NX-4V2 LED Keypad User Manual
2. Pressing the [1] key will make the keypad sounder go to higher tones,
pressing the [2] key will make the keypad sounder go to lower tones.
3. When the desired tone is reached, press the [#] key to set this tone and exit
from the “Adjust Tone” mode.
View alarm memory
1. Press [
∗
]-[3]. The zone(s) that created the last alarm will be displayed on the
keypad.
2. The ALARM MEMORY feature will flash those zones that created alarms and
will light steady those zones that were bypassed during the last alarm.
Test function - optional
If programmed, this function will perform a battery test, communicator test, and/or
a siren test. No alarms will be sent and no reports will be sent unless a
communicator test is performed, at which time a test signal will be sent.
1. Press [
∗
]-[4]. The test will be performed as programmed.
2. If the siren test is performed, enter a user code to silence the siren.
Walk test
If enabled, it will permit a temporary walk-through test where all zones become
silent and do not report alarms to the central station.
1. Press [
∗
]-[Chime]-[user code]. During this test the chime light will flash on the
LED keypad.
2. Each time a zone is faulted, the zone light on the LED keypad will illuminate
and the chime will sound. The number of the faulted zone(s) will be displayed
on the LCD keypad. It will also be entered into alarm memory and the internal
log.
3. The keypad will begin to beep after 15 minutes in this mode. This beeping
indicates t
hat the “Walk-Test” mode will be automatically exited in 5 minutes.
4. To exit at any time during this mode, enter a user code. Otherwise the Walk-
Test Mode@ will automatically exit after 20 minutes.
Reset function
This function is used to reset Smoke Detectors, Zone Troubles, and Zone
Tampers.
1. Disarm the system if not disarmed.
2. Press [
∗
]-[7]. Resets have now been performed.
3. If the keypad begins beeping, the reset did not execute properly. Enter your
code to silence the keypad. Wait a few minutes and repeat step 2 to attempt