beautypg.com

Injector and splitter installation – Interlogix POE302-MS User Manual

Page 11

background image

IFS POE302-MS Ethernet Injector User Manual 5

Injector and Splitter Installation

1. Connect the external power adaptor to the 56 VDC power

connector of the POE302-MS. The power LED will be lit.

2. Connect a standard network cable from the “Ethernet+DC”

port of the POE302-MS to the “PoE In” port of the POE302-
SP. The POE In-use LED of POE302-MS / POE302-SP will
remain lit showing operation.

3. Connect a standard network cable from the non-PoE

switch or other network device to the “Ethernet” port of
POE302-MS.

4. Select either 12VDC or 24VDC on the DC power output

switch and then connect the DC plug from "DC Out" of the
POE302-SP to the remote device.

5. Adjust proper DC power output and connect DC plug from

"DC OUT" of POE302-SP to remote device.

6. Power on the remote device and its power LED indicator

will remains on. Remote device will be powered upon
completion of the previous steps.

Figure 3: Injector and Splitter connection

Note:

According to the IEEE 802.3at Power over Ethernet

standard the POE302-MS will not inject power to the cable if it
is
not connected to IEEE 802.3at devices.