Led indicators, System, Vdsl/bnc – Interlogix MC251-4P/1CXT User Manual
Page 9: 10/100base-tx with poe port, Mode dip switch, Led indicators 5, System 5 vdsl/bnc 5, E-tx with poe port 5, Mode dip switch 5
IFS MC251-4P/1CXT User Manual 5
LED Indicators
System
LED
Color
Function
P1 Green
Light
Indicates that power 1 is active.
P2
Green Light indicates that power 2 is active.
FAULT Green Light indicates that either power 1 or power 2 does
not have power.
VDSL/BNC
LED
Color
Function
Light
Indicates that the VDSL link is established.
ACT
Green
Blink
Indicates that the VDSL link is actively sending or
receiving data over that port.
Light
Indicates that the VDSL link is established.
Fast
Blink
Indicates that the VDSL link is at training status
(about 10 seconds).
Sync
Green
Slow
Blink
Indicates that the VDSL link is at idle status.
Master
Green Light
Indicates that the VDSL Bridge is running in Master
mode.
Slave
Green Light
Indicates that the VDSL Bridge is running in Slave
mode.
10/100Base-TX with PoE Port
LED
Color
Function
Light
Indicates that the port is link up.
Blink
Indicates that the Converter is actively sending or
receiving data over that port.
LNK/
ACT
Green
Off
Indicates that the port is link down.
PoE
in-Use
Orange
Light
Indicate the port is providing 48V DC in-line power.
(Ports 1-4).
Mode DIP Switch
The MC251-4P/1CXT provides 4 selective transmission
modes. By switching the transmission modes, you can obtain
a best transmission mode to suit the phone line quality or