4 FAQ

4.1 Daily Maintenance

Please clean dome cover regularly to get vivid image.
Handle the cover with care. Use water to wash. Don’t use cloth to clean.
Use mild detergent to clean if there is too much dust.

Note:
The sweat from your hand may erode plating surface, your nail may scrape dome cover result in blur
image.

4.2 Problems and Solutions

SYMPTOM

CAUSE

SOLUTION

Red LED is not on.
z

Your power supplying does

not apply to the power. Or
connection is too loose.

z

Power off or transformer

problem.

z

Check power is connected or

properly earthed.

z

Check power supply condition

or check transformer.

1) No self-diagnosis,
no video signal
when I connect
dome to power.

Red LED light on the power
board is on
z

Power supplying is low

z

Something wrong with power
board.

z

Use multimeter to check

dome load.

z

Please contact retailer to
replace power board.

Power supplying is inadequate.

Replace power supplying.

2) No self diagnosis.
There is a noise

Mechanical malfunction.

Need electrical engineer help.

3) Video signal loss
occurs in high speed
rotation.

Power supplying is not sufficient

Replace power supplying.

Circuit connection is too loose. Connect

tightly.

4)Video signal is not
successive

Video switch or power problem

Need electrical engineer help.

Focus is in manual mode.

Control manually.

5) Video is not clear.

Dome cover is dirty.

Wash dome cover

6) During camera
switch, there is a tilt
movement in the
monitor.

Camera power is not in the same
Phase.

When several domes are
connected to one transformer,
please connect the transformer
output cable to the domes’ same
side.