Cisco XR 12000 Series Router SIP and SPA Hardware Installation Guide

OL-17438-04

Chapter 2 Overview: Cisco XR 12000 Series Router Shared Port Adapters

24-Port Channelized T1/E1/J1 ATM CEoP SPA Overview

RJ-45 Cable Pinouts

T1 lines from individual subscribers are attached to RJ-45 connectors on the front of the 24-port patch
panel. Each RJ-45 port accommodates an individual T1 subscriber line.

Pins 1 and 2 and 4 and 5 of the RJ-45 connectors are used for the 24-port CEoP SPA’s Transmit (TX)
and Receive (RX) signals. Depending on how the cable is installed between the SPA and its patch panel
(rear), the RJ-45 connectors operate as follows:

If the TX cable lead is connected to Transmit on the patch panel and RX is connected to Receive:

The SPA’s TX signals are transmitted on RJ-45 pins 1 (ring) and 2 (tip).

The SPA’s RX signals are received on RJ-45 pins 4 (ring) and 5 (tip).

If the TX cable lead is connected to Receive on the patch panel and RX is connected to Transmit:

RJ-45 pins 1 and 2 are used for the SPA’s RX signal.

RJ-45 pins 4 and 5 are used for the SPA’s TX signal.

Patch Panel Cabling

If you are connecting two 24-Port Channelized T1/E1/J1 ATM CEoP SPAs to each other, you must cable
both SPA’s patch panels together using a T1 cross-over cable or a T1 straight-through cable. The type of
cable you use (cross-over or straight-through) depends on how the CEoP SPAs are cabled to their patch
panels:

If both CEoP SPAs are connected to their patch panels in the same manner (TX to Transmit and
RX to Receive, or TX to Receive and RX to Transmit), use a T1 cross-over cable to connect the
patch panels to each other.

If both CEoP SPAs are connected to their patch panels in a different configuration (TX to Transmit
and RX to Receive on one SPA, and TX to Receive and RX to Transmit on the other SPA), use a
T1 straight-through cable (standard RJ-45 patch cable) between the patch panels.

24-Port Channelized T1/E1/J1 ATM CEoP SPA Patch Panel

The recommended patch panel is part number DCC2484/25T1S from SMP Data Communications
(

http://www.smpdata.com

).

To order the patch panel, contact the Sales and Marketing Support staff at SMP Data Communications:

800-880-7674 (toll free in the U.S.A.)

828-298-2260 (outside the U.S.A.)

[email protected]

(email)

Line 24

TX Tip

TX Ring

25

75

24

49

Not connected

RX Tip

RX Ring

49

99

Not connected

24

49

Table 2-50

24-Port Channelized T1/E1/J1 ATM CEoP SPA Cable Connector Pinouts (continued)

Subscriber

Connector Pins

Line

Signal

SPA

TX Cable Lead

RX Cable Lead