Power-on self test (post), Post error messages, Post – Compaq XL183 User Manual
Page 40: Running, Presario 1800 series
4 T
ROUBLESHOOTING
P
RESARIO
N
OTEBOOK
M
AINTENANCE
AND
S
ERVICE
G
UIDE
1800 S
ERIES
Presario 1800 Series
Models: XL180, XL181, XL182, XL183, XL184, XL185,
and XL190, XL191, XL192
Power-On Self Test (POST)
To run POST, complete these steps:
Turn off the Notebook, then turn it on again. As soon as the Compaq logo appears press the
ESC key to display the POST messages as they occur. Remember any POST error codes
that are displayed.
If the Notebook does not beep, POST has successfully completed its test and detected no
errors. The Notebook with automatically restart.
Note: If a bootable diskette is installed in the diskette drive, the system will boot from
the diskette instead of the hard drive.
However, if POST detects errors, the Notebook will beep and/or display a text message.
Note: If the Notebook is not functioning well enough to complete POST, or the display is
uable to show POST error messages, refer to the
later in this chapter.
POST Error Messages
A list of POST error codes and their descriptions are shown in the tables below.
102-System Board Failure
Probable Cause
Recommended Action
DMA, timers, and so on
Replace the system board
.
162-System Options Not Set
Probable Cause
Recommended Action
Incorrect configuration
Run Setup.
CMOS reflects an invalid
configuration setting.
Run Setup.
RAM failure
1.
Replace the memory
modules
.
2.
Replace the system board
.
Memory test data error
1.
Replace the memory
modules
.
2.
Replace the system board
.
XX000YZZ RAM failure
Replace the system board
.