Index (hex)

Type

Size Access Function

Description

2074

Int16

1

RW

Logic Input
Select

This Index is used to get or set Logic Input Function in a DAD141.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2074.
The values of the function are 0 or 1.
see also command description:

AI’n‘, ‘m‘ (n = 0 or 1) Assign Input.

2076

Int16

1

RW

Assign Logic
Input

This Index is used to get or set Logic Input Function in a DAD141.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2074.
The values of the function are 00 to 15.
see also command description:

AI’n‘, ‘m‘ (m = 0 … 15) Assign Input

2080

Float

2

R

Peak Value

This Index returns the latest peak value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 2080. See also command description:

GM Get Peak Value

2082

Int32

2

R

Peak Value

This Index returns the peak value of the DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 2082.
see also command description:

GM Get Peak Value

2084

Float

2

R

Hold

This Index returns the latest hold value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 2084. See also command description:

GH Get Hold Value

2086

Int32

2

R

Hold

This Index returns the hold value of the DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 2086.
see also command description:

GH Get Hold Value

2088

Float

2

R

Valley Value

This Index returns the latest valley value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 2088. See also command description:

GV Get Valley Value

208A

Int32

2

R

Valley Value

This Index returns the valley value of the DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 208A.
see also command description:

GV Get Valley Value

208C

Float

2

R

Peak to Peak
Value

This Index returns the latest valley value obtained from a DAD141.
The format is IEEE754 Single precision floating point format. The 32 bit data is obtained by reading 2
16-bit registers from index 208C. See also command description:

GO Get Peak Value

208E

Int32

2

R

Peak to Peak
Value

This Index returns the peak value of the DAD141.
The 32 bit integer data is obtained by reading 2 16-bit registers from index 208E.
see also command description:

GO Get Peak Value

2100

Int32

2

RW

Analog Action

This Index is used to select Analog Output Source.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2100.
The values of the analog action are 0 to 8.
see also command description:

AA Analog output source

Index (hex)

Type

Size Access Function

Description