beautypg.com

Installing to wall, Notice, Warning – Desa Tech CGN20T User Manual

Page 9: Caution

background image

9

103873

INSTALLING TO

WALL

NOTICE

A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call
dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have the items listed below.

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• manual shutoff valve *
• ground joint union

• test gauge connection * (see

Figure 12, page 15)

• sediment trap
• tee joint
• pipe wrench

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 30.

LOCATING HEATER

This heater is designed to be mounted on a wall.

WARNING ICON

G 001

WARNING

Maintain the minimum clearances shown in Figure 4 (page 10). If you
can, provide greater clearances from floor, ceiling, and joining wall.

You can locate heater on floor, away from a wall. An optional floor mounting stand is
needed. Purchase the floor mounting stand from your dealer. See Accessories, page 30.

WARNING ICON

G 001

WARNING

Never install the heater

• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are

less than 36 inches from the front, top, or sides of the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

WARNING ICON

G 001

CAUTION

This heater creates warm air currents. These currents move heat to
wall surfaces next to heater. Installing heater next to vinyl or cloth
wall coverings or operating heater where impurities in the air (such
as tobacco smoke) exist, may discolor walls.

Continued

IMPORTANT:

Vent-free heaters add moisture to the air. Although this is beneficial,

installing heater in rooms without enough ventilation air may cause mildew to form
from too much moisture. See Fresh Air for Combustion and Ventilation, pages 5
through 8.