beautypg.com

Operating heater, Caution – Desa Tech CGN20T User Manual

Page 18

background image

18

103873

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near

the floor. If you smell gas, STOP! Follow “B” in the safety information at the
top of page 17. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise

C-clockwise

to the PILOT position. Press in

control knob for five (5) seconds (see Figure 16).

Note:

You may be running this heater for the first time after hooking up to

gas supply. If so, the control knob may need to be pressed in for 30 seconds.
This will allow air to bleed from the gas system.

• If control knob does not pop up when released, contact a qualified

service person or gas supplier for repairs.

6. With control knob pressed in, push down and release ignitor button. This will

light pilot. The pilot is attached to the front of burner. The pilot can be seen
through the glass panel. If needed, keep pressing ignitor button until pilot
lights.

Note:

If pilot does not stay lit, refer to Troubleshooting, pages 22 through

25. Also contact a qualified service person or gas supplier for repairs. Until
repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure
, page 19.

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob.

OPERATING

HEATER

WARNING ICON

G 001

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

Note:

If pilot goes out, repeat steps 3 through 7. This heater has a safety

interlock system. Wait one (1) minute before lighting pilot again.

8. Turn control knob counterclockwise

C-clockwise

to desired heating level. The

main burner should light. Set control knob to any heat level between HI and
LO.

Thermocouple

Ignitor Electrode

Figure 17 - Pilot

Pilot Burner