For convenience and efficiency, install heater

• where there is easy access for operation, inspection, and service
• in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 30. If plan-
ning to use fan, locate heater near an electrical outlet.

Figure 4 - Mounting Clearances As Viewed From Front of Heater

INSTALLING TO

WALL

Continued

WARNING ICON

G 001

CAUTION

If you install the heater in a home garage

• heater pilot and burner must be at least 18 inches above floor
• locate heater where moving vehicle will not hit it

Minimum
From
Sides Of
Heater

36"

3"

FLOOR

CEILING

Minimum

Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material

6"

Left
Side

Right
Side

Figure 5 - Attaching Thermostat Sensing Bulb

Clamp

Thermostat
Sensing Bulb

THERMOSTAT SENSING BULB

The thermostat sensing bulb has been placed inside the heater for protection during
shipping.

Locating Thermostat Sensing Bulb

1. Remove front panel of heater (see Figure 7, page 11).
2. Locate thermostat sensing bulb just under burner assembly.

IMPORTANT:

Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1. Remove thermostat sensing bulb from holders inside heater. Route through slot

opening in bottom of heater.

2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in

hardware package.

3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is

located on lower left edge on back of heater. Make sure the thermostat sensing
bulb is pointing up.