103873

TROUBLE-

SHOOTING

Continued

OBSERVED
PROBLEM

Burner does not light
after ODS/pilot is lit

Delayed ignition of
burner

Burner backfiring
during combustion

Yellow flame during
burner combustion

Slight smoke or odor
during initial opera-
tion

Heater produces a
whistling noise when
burner is lit

REMEDY

1. Clean burner (see Clean-

ing and Maintenance,
page 22) or replace burner
orifice

2. Replace burner orifice

3. Contact local natural gas

company

1. Contact local natural gas

company

2. Clean burner (see Clean-

ing and Maintenance,
page 22) or replace burner
orifice

1. Clean burner (see Clean-

ing and Maintenance,
page 22) or replace burner
orifice

2. Replace burner
3. Replace gas regulator

1. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 22)

2. Replace gas regulator

1. Problem will stop after a

few hours of operation

1. Turn control knob to LO

position and let warm up
for a minute

2. Operate burner until air is

removed from line. Have
gas line checked by local
natural gas company

3. Observe minimum installa-

tion clearances (see Figure
4, page 10)

4. Clean burner (see Clean-

ing and Maintenance,
page 22) or replace burner
orifice

POSSIBLE
CAUSE

1. Burner orifice is

clogged

2. Burner orifice diameter

is too small

3. Inlet gas pressure is

too low

1. Manifold pressure is

too low

2. Burner orifice is

clogged

1. Burner orifice is

clogged or damaged

2. Burner damaged
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

1. Residues from manu-

facturing processes

1. Turning control knob

to HI position when
burner is cold

2. Air in gas line

3. Air passageways on

heater blocked

4. Dirty or partially

clogged burner orifice

This manual is related to the following products: