beautypg.com

Inspecting burner – Desa Tech CGN20T User Manual

Page 20

background image

20

103873

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

Thermocouple

Pilot Burner

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 19 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 19.

• turn heater off (see To Turn Off Gas to Appliance, page 19).
• see Troubleshooting, pages 22 through 25.