1. Remove plastic plug from belt guard, set aside for later use.

2. Use a socket wrench to loosen left-hand thread retaining nuts. Be sure the socket is over the outer retaining nut

only. The outer retaining nut has to be loosened first and removed, then remove the second retaining nut, use

another wrench to hold the other end of the shaft during this procedure.

3. Be careful not to damage threads on end of shaft when removing or installing the drum. Support the weight of the

drum to minimize the possibility of damage.

4. With the left-hand thread retaining nuts removed, use a socket wrench to turn the other end of the shaft in a clock-

wise direction for removal. Support drum during shaft removal so the drum will not fall when the shaft is removed,

possibly causing damage to machine and personal injury.

5. Once the drum is removed, maintenance and/or cutter replacement can be performed.

6. Reverse this procedure for reassembly insuring the drive studs are lined up with drive holes in drum before insert-

ing the main shaft. Be sure to install plastic plug removed in step #1.

CPL-8/CPM-8 DRUM REMOVAL / REPLACEMENT