CA‐NET Protocol

 

page  5 / 29 

 

ignored  those  exceeding  this  limit.  Blank  characters  are  not  allowed.  A  valid  example: 

 

MAIN_HALL

 

 are text strings (without blank spaces) that identify the LCD display working 

mode. In the CA200z there are just three possible values for this parameter: 

o

ON 

o

DIMMED 

o

OFF 

  are  numerical  values  in  the  [0…100]  range  that  define  the  LCD  display 

contrast level. 

  are  text  strings  (without  blank  spaces)  that  identify  the  Talkover  /  Pager 

function assignment for a MIC input towards the device’s outputs. In the CA200z there are 
just five possible values for this parameter: 

o

OFF 

o

ZA 

o

ZB 

o

ZA‐B 

o

PAGER 

 is a numerical value that defines the Talkover function priority of one MIC input in 

front of the other inputs in the unit. In the case of the CA200z just two values are valid [1, 
2], being “1” the highest priority level and “2” the lower one. 

 is a numerical value for an error code. 

  is  a  text  chain  inside  double  quotation  marks,  containing  an  error 

description. 

 

DAM514 NOTES: 

 

parameter 

Originally designed to connect WPmVOL‐SR (or WPTOUCH) wall panels to the REMOTE ports 
in  the  DAM514:  panels  that  include  a  volume  control  knb  and  a  5‐position  selector  knob. 
The possible working modes (

REMOTE_MODE 

command) of any of the 4 available remote 

ports (R1 to R4) in the unit are: 

o

DISABLED 

o

IN_VOL: volume control for one or several inputs (general input volume, affecting all 
the post processing) 

o

ZONE_VOL: volume control for one or several zone outputs 

o

IN_SEL:  one  input  (source)  selection  for  one  or  several  output  zones  (with  the  5 
position selector)