Ecler CA‐NET RS‐232 User Manual
Page 23
CA‐NET Protocol
page 23 / 29
volume, affecting all the post processing)
IN_BASS
Sets the current BASS tone LEVEL for the specified INPUT
IN_MID
Sets the current MIDDLE tone LEVEL for the specified INPUT
IN_TREBLE
Sets the current TREBLE tone LEVEL for the specified INPUT
HPF_ACTIVE
ON/OFF
Sets the current HIGH PASS FILTER status (ON or OFF) for the
specified INPUT
HPF_FREQUENCY
Sets the current HIGH PASS FILTER frequency (Hz) for the specified
INPUT
FBS_ACTIVE
ON/OFF
Sets the current FEEDBACK SUPPRESSOR feature status (ON or OFF)
for the specified INPUT
GATE_ACTIVE
ON/OFF
Sets the current NOISE GATE status (ON or OFF) for the specified
INPUT
GATE_THRESHOLD
Sets the current NOISE GATE THRESHOLD LEVEL (dBx10) for the
specified INPUT
GATE_DEPTH
Sets the current NOISE GATE DEPTH (attenuation when gate is
closed, dBx10) for the specified INPUT
GATE_ATTACK
Sets the current NOISE GATE ATTACK TIME (milliseconds x10) for
the specified INPUT
GATE_HOLD
Sets the current NOISE GATE HOLD TIME (milliseconds x10) for the
specified INPUT
GATE_RELEASE
Sets the current NOISE GATE RELEASE TIME (milliseconds x10) for
the specified INPUT
TALKOVER_ACTIVE
ON/OFF
Sets the current TALKOVER status (ON or OFF) for the specified
INPUT
TALKOVER_MODE
PAGER/DUCKER
Sets the TALKOVER function working mode (PAGER or DUCKER) for
the specified INPUT
TALKOVER_PRIORITY
LOW/HIGH
Sets the current TALKOVER PRIORITY level (LOW or HIGH) for the
specified INPUT
TALKOVER_ZONES
Sets the current TALKOVER assignment to outputs (ZONES) for the
specified INPUT. Zones parameter can include ZA to ZD, separated
by comma characters and no blank space (example: ZA,ZC,ZD)
TALKOVER_THRESHOLD
Sets the current TALKOVER THRESHOLD LEVEL (dBx10) for the
specified INPUT