Ecler CA‐NET RS‐232 User Manual
Page 24
CA‐NET Protocol
page 24 / 29
TALKOVER_DEPTH
Sets the current TALKOVER DEPTH (attenuation, dBx10) for the
specified INPUT
TALKOVER_ATTACK
Sets the current TALKOVER ATTACK TIME (milliseconds x10) for the
specified INPUT
TALKOVER_HOLD
Sets the current TALKOVER HOLD TIME (milliseconds x10) for the
specified INPUT
TALKOVER_RELEASE
Sets the current TALKOVER RELEASE TIME (milliseconds x10) for the
specified INPUT
CHIME_MELODY
Sets the current CHIME MELODY selected for the TALKOVER
function in PAGER mode
CHIME_VOL
Sets the current CHIME MELODY VOLUME (dBx10) adjusted for the
TALKOVER function in PAGER mode
XSELECT
ON/OFF
Sets the current CROSSPOINT SELECT status (ON (input active) or
OFF (input muted)) for the specified INPUT at the specified output
zone
XLEVEL
Sets the current CROSSPOINT LEVEL (mix level) for the specified
INPUT at the specified output zone
ZONE_LABEL
“
Sets the current LABEL (name) for the specified output zone
(between quotation marks to allow for blank characters in the label)
ZONE_STEREO
ON/OFF
Sets the current STEREO link status (ON or OFF) the specified output
zone
ZONE_MUTE
ON/OFF
Sets the current MUTE status (ON or OFF) for the specified output
zone
ZONE_VOL
Sets the current VOLUME for the specified output zone
GEQ_ACTIVE
ON/OFF
Sets the current GRAPHICAL EQUALIZER status (ON or OFF) for the
specified output zone
GEQ_GAIN
GRAPHICAL EQUALIZER for the specified output zone
XOVER_ACTIVE
ON/OFF
Sets the current CROSSOVER FILTER status (ON or OFF) for the
specified output zone
XOVER_TYPE
LP/HP
Sets the current CROSSOVER FILTER TYPE (LP or HP) for the
specified output zone
XOVER_FREQUENCY
Sets the current CROSSOVER FILTER FREQUENCY (Hz) for the