beautypg.com

Ecler DAM514 User Manual

Page 11

background image

11

MUTE connector

The rear panel MUTE connector allows the connection of an external potential free contact

closure to mute one or several output zones of the device, when an external unit is activating it
(example: a central alarm system for emergencies and evacuation). The MUTE port affects the outputs
selected from the device setup menu (front keys and LCD display) or from EclerCOMM Manager
application software (see chapter 9 for more information).

RS-232 port

The RS-232 serial communication port allows remote management of DAM514 from a computer

or external control system supporting theCA-NET protocol, or from the free EclerCOMM Manager
application software.


See the manual of the CA-NET protocol for complete information about the details of the

connection and the syntax of supported commands.


The specifications of the DAM514 serial connection are

o Baud rate: 9600 (Fixed, without auto-negotiation)
o Data bits: 8
o Parity:

None

o Stop bits: 1
o Flow control: None
o Cable: standard RS-232 type, DB9-DB9 (pin-to-pin)