Ecler DAM514 User Manual
Page 106
106
13. TECHNICAL CHARACTERISTICS
13. CARACTERÍSTICAS TÉCNICAS
13. CARACTÉRISTIQUES TECHNIQUES
13. TECHNISCHE DATEN
INPUT 1, 2, 3 (LINE)
Sensitivity
0 / -6dBV Internal jumper adjust. 0dBV factory default
Input impedance
>13k
Input connector
RCA female
INPUT 4, 5 (MIC)
Sensitivity
-20 / -50dBV External potentiometer adjust
Input impedance
>24k electronically balanced
CMRR
>55dB (20Hz ÷ 20kHz)
Input connector
Terminal block (Symmetrical)
INPUT 4, 5 (LINE)
Sensitivity
0 / -6dBV Internal jumper adjust. 0dBV factory default
Input impedance
>24k electronically balanced
CMRR
>55dB (20Hz ÷ 20kHz)
Input connector
Terminal block (Symmetrical)
ZONE OUTPUTS
Nominal output level
0dBV
Output impedance
300
electronically balanced
Output connector
Terminal block (Symmetrical)
A/D & D/A
24bit / 48kHz
FREQUENCY RESPONSE
<10Hz ~ 20kHz (+0dB/ -0.5dB)
OUTPUT NOISE FLOOR (FFT)
>110dB (from 20Hz to 20kHz)
THD + NOISE
< 0.0058% (1kHz, 1Vrms)
CROSSTALK
>90dB, 20Hz ÷ 20kHz
INPUT EQ
Type
Baxandall 3 ways EQ
Gain
-10dB ~ +10dB in 0.1dB steps
Frequency
Low 200Hz Mid 1kHz High 6.3kHz
ZONE OUTPUT EQ
Type
10 band EQ
Filters
Adaptable Q to achieve maximum flat response
Gain
-10dB ~ +10dB step 0.1dB
Frequencies
31, 63, 125, 250, 500, 1k, 2k, 4k, 8k, 16k Hz
OUTPUT CROSSOVER FILTERS
Type
Low & High Pass Butterworth 12 dB/oct
Frequency
20Hz ÷ 20kHz
INPUT 4, 5 TALKOVER
Type
Assignable to any output zone. 2 priority levels.
Modes
Ducker / Pager (only input 5)
Threshold
-80 / +12dBV
Depth
0 ~ 80dB
Attack time