CA‐NET Protocol

 

page  6 / 33 

 

 is a numerical value for an error code. 

  is  a  text  chain  inside  double  quotation  marks,  containing  an  error 

description. 

 

DAM514 NOTES: 

 

parameter 

Originally designed to connect WPmVOL‐SR (or WPTOUCH) wall panels to the REMOTE ports 
in  the  DAM514:  panels  that  include  a  volume  control  knb  and  a  5‐position  selector  knob. 
The possible working modes (

REMOTE_MODE 

command) of any of the 4 available remote 

ports (R1 to R4) in the unit are: 

o DISABLED 
o IN_VOL: volume control for one or several inputs (general input volume, affecting all 

the post processing) 

o ZONE_VOL: volume control for one or several zone outputs 
o IN_SEL:  one  input  (source)  selection  for  one  or  several  output  zones  (with  the  5 

position selector) 

o IN_SEL_IN_LEVEL: one input (source) selection for one or several output zones (with 

the 5 position selector) + the  control of the selected input’s crosspoints level to the 
destination zones 

o IN_SEL_ZONE_VOL:  one  input  (source)  selection  for  one  or  several  output  zones 

(with the 5 position selector) + the  control of the affected zones output volume  

o PRESET: a preset recovery, from P1 to P5 (with the 5 position selector) 
o PRESET_ZONE_VOL: a preset recovery, from P1 to P5 (with the 5 position selector) + 

volume control for one or several zone outputs 

PAGER 

DUCKER 

parameter for 

TALKOVER_MODE 

command: 

o INPUT 5 can be used with the Talkover feature in PAGER or DUCKER mode. PAGER 

mode requires an external paging station (MPAGE4) to select the destination zones 
and performing the paging 

o INPUT 4 can be used with the Talkover feature just in DUCKER mode